arXiv:quant-ph/0609194AbstractReferencesReviewsResources
Demonstration of the difference Casimir force for samples with different charge carrier densities
F. Chen, G. L. Klimchitskaya, V. M. Mostepanenko, U. Mohideen
Published 2006-09-26Version 1
A measurement of the Casimir force between a gold coated sphere and two Si plates of different carrier densities is performed using a high vacuum based atomic force microscope. The results are compared with the Lifshitz theory and good agreement is found. Our experiment demonstrates that by changing the carrier density of the semiconductor plate by several orders of magnitude it is possible to modify the Casimir interaction. This result may find applications in nanotechnology.
Comments: 4 pages, 4 figures, to appear in Phys. Rev. Lett
Journal: Phys. Rev. Lett., v.97, N 17, p.170402-1-4 (2006).
Categories: quant-ph, cond-mat.mtrl-sci
Keywords: carrier density, difference casimir force, charge carrier densities, demonstration, atomic force microscope
Tags: journal article
Related articles: Most relevant | Search more
Demonstration of optically modulated dispersion forces
arXiv:0802.3733 [quant-ph] (Published 2008-02-26)
Experimental procedures for precision measurements of the Casimir force with an Atomic Force Microscope
arXiv:1801.06316 [quant-ph] (Published 2018-01-19)
Demonstration of Topological Data Analysis on a Quantum Processor
He-Liang Huang et al.