arXiv Analytics

Sign in

arXiv:0901.3138 [astro-ph.HE]AbstractReferencesReviewsResources

The angular resolution of the Pierre Auger Observatory

C. Bonifazi, for the Pierre Auger Collaboration

Published 2009-01-20Version 1

We discuss the angular resolution obtained for events registered with the surface detector alone and for hybrid events, i.e., those observed simultaneously by both the surface and fluorescence detectors. The angular accuracy of the surface detector is directly extracted from the data itself and on an event by event basis, and is given as a function of the number of stations triggered by the event and of the zenith angle of the shower. We compare the angular resolution of the surface detector obtained from hybrid events with the one obtained from the surface detector alone.

Comments: 6 pages, 8 figures. Presented at CRIS 2008, Malfa, Italy
Journal: Nucl.Phys.Proc.Suppl.190:20-25,2009
Categories: astro-ph.HE
Related articles: Most relevant | Search more
arXiv:0902.4613 [astro-ph.HE] (Published 2009-02-26)
Measurements of the Muon Content of UHECR Air Showers with the Pierre Auger Observatory
arXiv:0901.2153 [astro-ph.HE] (Published 2009-01-15)
Monte-Carlo studies of the angular resolution of a future Cherenkov gamma-ray telescope
arXiv:1710.07249 [astro-ph.HE] (Published 2017-10-19)
Inferences on Mass Composition and Tests of Hadronic Interactions from 0.3 to 100 EeV using the water-Cherenkov Detectors of the Pierre Auger Observatory